How To: "Unable to load DLL ‘Microsoft.VisualStudio.QualityTools.RecorderBarBHO100.dll’: The specified module could not be found"

18/11/2010

How To: "Unable to load DLL ‘Microsoft.VisualStudio.QualityTools.RecorderBarBHO100.dll’: The specified module could not be found"

Working on a new environment trying to perform an new Web Test I was faced two issues:

1. Web Test Recorder doesn’t show up

Problem :When I start my recording Internet Explorer comes up but the Web Test Recorder doesn’t show up.

Solution: In IE enter Tools menu Select Explorer Bars and Click “Web Test Recorder 10.0” – (This will work for Web Test 8.0 and 9.0)

image

 

2. Cannot Stop Web Test Recording Without Getting Exception

image

Problem: When I clicked “Stop” in the end of Web Test Recording I get the following Exception: "Unable to load DLL ‘Microsoft.VisualStudio.QualityTools.RecorderBarBHO100.dll’: The specified module could not be found"

Solution:

Copy Microsoft.VisualStudio.QualityTools.RecorderBarBHO100.dll (For older versions RecorderBarBHO90.dll  etc)

Located under C:\Program Files (x86)\Microsoft Visual Studio 10.0\Common7\IDE\PrivateAssemblies\

To – C:\Program Files\Internet Explorer and for 64bit machines also Copy To – C:\Program Files (x86)\Internet Explorer

Enjoy

Add comment
facebook linkedin twitter email

Leave a Reply

5 comments

  1. Shreeni26/05/2011 ב 15:14

    Thanks for that info 🙂

  2. Raphael Soares11/08/2011 ב 00:13

    Thanks a lot, my problem is solved with our tip.

  3. bartdk14/03/2012 ב 11:46

    Thanks 🙂

    kind regards,
    bart

  4. Gholamreza18/08/2012 ב 06:55

    Thanks man 🙂
    Problem is solved by this tip
    Reza